From 1a7d3b8f9ebfbc32bc5dc9bf1ca8a8fcdc9cbf48 Mon Sep 17 00:00:00 2001 From: Bill Zissimopoulos Date: Sat, 14 May 2016 21:01:29 -0700 Subject: [PATCH] launcher: remove JOB_OBJECT_LIMIT_BREAKAWAY_OK, use JobControl=0 registry setting instead --- src/launcher/launcher.c | 3 +-- 1 file changed, 1 insertion(+), 2 deletions(-) diff --git a/src/launcher/launcher.c b/src/launcher/launcher.c index a238befd..e80a51d3 100644 --- a/src/launcher/launcher.c +++ b/src/launcher/launcher.c @@ -628,8 +628,7 @@ static NTSTATUS SvcStart(FSP_SERVICE *Service, ULONG argc, PWSTR *argv) JOBOBJECT_EXTENDED_LIMIT_INFORMATION LimitInfo; memset(&LimitInfo, 0, sizeof LimitInfo); - LimitInfo.BasicLimitInformation.LimitFlags = - JOB_OBJECT_LIMIT_BREAKAWAY_OK | JOB_OBJECT_LIMIT_KILL_ON_JOB_CLOSE; + LimitInfo.BasicLimitInformation.LimitFlags = JOB_OBJECT_LIMIT_KILL_ON_JOB_CLOSE; if (!SetInformationJobObject(SvcJob, JobObjectExtendedLimitInformation, &LimitInfo, sizeof LimitInfo)) {